AccuThermo AW 410
AccuThermo AW 610
AccuThermo AW 810
AccuThermo AW 820
AccuThermo AW 830
AccuThermo AW 610V
AccuThermo AW 820V
AccuThermo AW 860V
Heatpulse 210 Spare Parts
Heatpulse210 Manual
Minipulse 310 Spare Parts
Minipulse310 Manual
Heatpulse 410 Spare Parts
Heatpulse410 Manual
Heatpulse 610 Spare Parts
Heatpulse610 Manual
Heatoulse 610 I Spare Parts
Heatpulse610I Manual
Heatpulse 210 Service
Heatpulse210 Refurbishment
Heatpulse210 Upgrade
Minipulse 310 Service
Minipulse310 Refurbishment
Minipulse 310 RTA Upgrade
Heatpulse 410 Service
Heatpulse 410 Refurbishment
AG Associates Heatpulse410 Upgrade
Heatpulse 610 Service
Heatpulse610 Refurbishment
AG 610 Rapid Thermal Process Upgrate
Heatpulse 610 I Service
Heatpulse610I Refurbishment
AG 610I Rapid Thermal Anneal Upgrade
Rapid Thermal Process
Atmospheric Rapid Thermal Processors
Vacuum Rapid Thermal Processors
Why not sell used Hearpulse 210/410/610 RTA
Temperature Measured vs. Actual
Contact Us
Site Map


AccuThermo AW 610V Vacuum RTA RTP   

The AccuThermo AW 610V  is a manual desktop vacuum rapid thermal processing (RTP) system for 2 to 4 inch or 4 to 6 inch wafers, which uses high intensity visible radiation to heat single wafers for short process periods of time at precisely controlled temperatures and vacuum. The process periods are typically 1-600 seconds in duration, although periods of up to 9999 seconds can be selected. These capabilities, combined with the heating chamber's cold-wall design and superior heating uniformity, provide significant advantages over conventional furnace processing.The AccuThermo RTP system consists of an oven unit and a controller computer running. The wafer to be processed is placed on a quartz tray that slides into the chamber with  quartz window plate in the oven unit. The lamps above the quartz window provide the source of energy for heating the wafer. The lamps can be controlled manually and automatically from the controller computer.

The AW-900 control software allows full control and diagnostics of the AccuThermo RTP system. In addition, it allows the creation of recipes for automated control of the temperature and, optionally, process gas flow. The control software uses a set of operating instructions known as recipes to automatically control the AccuThermo RTP system. These recipes are created by the Process Engineer to monitor and control the parameters of the processing cycle. The Operator then uses the software to select and run the process parameters (steady state temperature, process time, ramp rates, etc.). The AW-900 software is also used to create, delete, copy, modify and store the recipes and to execute system diagnostics.
  1. Vvacuum
  2. Closed-loop temperature control with pyrometer or thermocouple temperature sensing.
  3. Precise time-temperature profiles tailored to suit specific process requirements.
  4. Fast heating and cooling rates unobtainable in conventional technologies.
  5. Consistent wafer-to-wafer process cycle repeatability.
  6. Elimination of external contamination.
  7. Small footprint and energy efficiency.
  8. The watchdog timer shuts down the lamps to prevent run-away heating of the wafer.
  1. The AccuThermo RTP system is a versatile tool that is useful for many applications:
  2. Ion Implant Activation
  3. Polysilicon Annealing
  4. Oxide Reflow
  5. Silicide Formation
  6. Contact Alloying
  7. Oxidation and Nitridation
  8. GaAs Processing
The following list contains the key features of the AccuThermo RTP system heating, cooling and temperature measurement systems:
  1. High-intensity visible radiation heats wafers for short periods of 1 to 9999 seconds at precisely controlled temperatures in the 400C to 1200C range. (1 to 600 second heating periods are used typically.)
  2. Tungsten halogen lamps and cold heating chamber walls respectively allow fast wafer heating and cooling rates.
  3. The system delivers time and temperature profiles tailored to suit specific process requirements.
  4. Pyrometer or thermocouple sensing offers precise closed-loop temperature control.
  5. Cooling N2 flows around the lamps and quartz isolation tube
  6. MFC controlled gases (up to six) flow through the heating chamber for purge and/or process purposes.
Following are the specifications for the AccuThermo Rapid Thermal Processor (RTP) system.
  1. Vacuum: vacuum
  2. Wafer handling: Manual loading of wafer into the oven, single wafer processing.
  3. Wafer sizes: 2", 3", 4"  or 4",5" 6" wafers.
  4. Ramp up rate: Programmable, 10C to 200C per second.
  5. Recommended steady state duration: 0-300 seconds per step.
  6. Ramp down rate: Programmable, 10 C to 250 C per second.Ramp down rate is temperature-and-radiation-dependent and the maximum is 125 C per second.
  7. Recommended steady state temperature range: 150C - 1150 C
  8. ERP temperature accuracy: 1C, when calibrated against an instrumented thermocouple wafer (ITC).
  9. Thermocouple temperature accuracy: 0.5C
  10. Temperature repeatability: 0.5C or better at 1150C wafer-to-wafer. (Repetition specifications are based on a 100-wafer set.)
  11. Temperature uniformity: +5C across a 6" (150 mm) wafer at 1150C. (This is a one sigma deviation 100 angstrom oxide.) For a titanium silicide process, no more than 4% increase in non-uniformity during the first anneal at 650C to 700C.
  12. Process/Purge gas inputs: Any inert and/or non-toxic gas regulated to 30 PSIG and pre-filtered to 1 micron. Typically, Nitrogen (N2), oxygen (O2), argon (Ar), and/or helium (He) are used.+2.5C


Rapid Thermal Process
Atmospheric Rapid Thermal Processors
Vacuum Rapid Thermal Processors
Why not sell used Hearpulse 210/410/610 RTA
Temperature Measured vs. Actual